Denas Therapy - What is necessary to know before starting to use devices?

What is necessary to know before starting to use devices?

Device Modes of Operation

Level of Energy Influence of Apparatuses

Device Modes of Operation
There are two modes of operation of apparatuses of DENS-therapy which should be combined and altered.

Dosed Mode
While operating under this mode, the body, due to availability of "biological" feedback, himself specifies the required time of the apparatus performance thus performing self-regulation.
A light and sound signal is produced upon completion of the required exposure.

While operating under the dosed mode, electrodes of the apparatus should be installed on the required zone of only dry skin. Electrodes should be applied to the next zone only after the signal is produced. It is not allowed to move electrodes along the skin while operating under the dosed mode.

The dosed mode is applied in order to reveal trigger (starting, pathogenic) zones, zones of asymmetry, for operation with the skin of the sound pair organ or a part of the body, at uncertain (non-localized) complaints.

Constant Mode
Under the constant mode apparatuses function as transcutaneous electric neurostimulators. The duration of the session should be determined by an operator in compliance with the technique described in the Denas Manual.

While operating under the constant mode, electrodes of the apparatus can be re-arranged as well as moved along the skin surface with a speed of 1 -2 cm per second (scanning). The constant mode is applied at localized complaints, at emergency aid, with the therapeutic purpose and for treatment of revealed trigger zones and zones of asymmetry.

While treating with apparatuses one and the same skin zone successively follow only the next order of repetition of the said modes: first the dosed mode, than the constant mode.

Level of Energy Influence of Apparatuses

Minimum Energy Level
At installation of electrodes of the engaged apparatus on the skin the patient does not experience any subjective sensations (pain, pricking). This level is primarily used at operation under the dosed mode and at treating children.

Comfortable Energy Level
At installation of electrodes of the engaged apparatus on the skin the patient experiences slight non irritating pricking. This level can be used at operation under the dosed mode at treating teenagers and adults, at emergency aid, with the therapeutic purpose and for treating revealed trigger zones and zones of asymmetry.

Maximum Energy Level
At installation of electrodes of the engaged apparatus on the skin the patient experiences pricked pain as at a light electric discharge which may be accompanied by spontaneous contraction of muscles located near the installed electrodes. This level is used at the expressed pain syndrome, at emergency aid, unconscious state of the patient.

Important! It should be taken into account that:
- DENAS, at its engagement, is always adjusted at the minimum energy level;
- DENAS has the light diode scale of power level basing on which each patient can objectivize the degree of his sensations.
Back to Home Page
Denas devices are listed in Australian Register of Therapeutic Goods 
Official website of “Denas MS” Corporation distributor and Dens Practitioner
© 2008 Denas Therapy World. Website: www.denastherapy.com.au
Address: 9 Verdun Place Engadine, NSW 2233, Australia
Ph: 61 2 9520 1806 Mob: 0431 636 414 Email: info@
denastherapy.com.au

 

Rambler's Top100
Rambler's Top100